Length (cm)
Width (cm)
Height (cm)
Weight (kg)
Length (cm)
Width (cm)
Height (cm)
Weight (kg)
354
115
187
2390
254
86
187
1,830
- Set Mounted Tropical Duty Radiator
- Engine Driven Cooling Fan with Protection Guard
- Radiator Stone Guard
- Fuel, Lubricating Oil and Air Filter(s) with Restriction Indicator(s)
- Electronic Engine Management System
- 24 Volt electric start with charging alternator
- Protection Switches for
- Low oil pressure
- High Engine Temprature
- Low coolant level
- Wiring to Control Panel
- Steel base frame with integral 8 hour capacity fuel tank, complete with contents gauge, steel wire braded fuel lines, fill, vent and drain fittings
- Anti vibration mountings fitted between the engine/alternator feet and base
- Set mounted Yuasa maintenance free lead acid battery with leads and terminals
- Exhaust flexible section(s) with connections
- S.L.S. exhaust Silencer(s) supplied loose
- Load and function tests
- Paint finish to our standard scheme
- Comprehensive user manual
Manual Start (Upto 1600 A)
Alternator mounted profile control panel comprising -
- Ammeter per phase
- 1 x voltmeter
- Voltmeter selector switch
- Dual scale frequency/RPM indicator
- Hour counter
- 3 pole MCB/MCCB Mounted in control panel (1)
- Key Start/Stop switch (701 module fitted to 1300 series)
- Shutdown indicator for
- High Engine Temperature
- Low oil pressure
- Low coolant level
- Overspeed
- Oil Pressure Gauge
- Water temperature gauge
- Battery voltmeter
- Diagnostic socket
Keystart (Above 1600 A)
As above but with ACB mounted in a separate freestanding cubicle
Auto Start (Upto 909 A)
As keystart but comprising the following additions -
- Constant Potential barrety charger
- Battery charger On/Off pushbutton
- Deep Sea 521K autostart module
- Off/Auto/Manual selector keyswitch
- Indicators for
- Power On
- Remote start present
- Charge Fail
- Common Alarm
- Fail to start
- Multi attempt to start programme
- Programmed timers for
- Delay on start
- Mains restoration
- Run on for engine cooling
- Crank period
- Protected Override
- Diagnostic socket for engines with electronic management
Auto Start (Above 909 A without MCCB)
As above but excludng MCCB
ATS (Upto 1000 A)
Wall mounted enclosure comprising -
- 4 Pole changeover contactors
- Indicators for
- Mains available
- Mains on load
- Generator Available
- Generator on load
- Phase failure monitor
ATS (Above 1000 A)
As above but
- 1000 A to 1250 A with motor operated MCCN's
- 1600 and above with motor operated ACB's